Nicholas O. Lindan wrote:
> "john" <x@[EMAIL PROTECTED]
> wrote
>
>> Aristo also has a device to allow the use of digital timers [with a
>> T-12]. Is it necessary with the F-Stop timer?
>
> It shouldn't be.
>
[snip]
> I don't know the inductive characteristics of the T-12 and don't have
any
> experience with this unit. My guess is it will work, but there is a
> chance the external 'solid state contactor' may be needed. In any case,
> plugging the head in and seeing if it works will cause no damage to the
> timer.
>
I do not know the inductive characteristics of cold light heads either.
If the load on the step up transformer were resistive, the load would be
reflected back through the transformer and place a resistive load on the
timer and the power company. Now a gas discharge tube is not resistive,
but
it probably has a resistor in series with it to reduce the peak current
through the tube, so it may be more resistive than the tube itself.
--
.~. Jean-David Beyer Registered Linux User 85642.
/V\ PGP-Key: 9A2FC99A Registered Machine 241939.
/( )\ Shrewsbury, New Jersey http://counter.li.org
^^-^^ 20:50:01 up 10 days, 13:22, 3 users, load average: 4.61, 4.50, 4.33


|